<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>انجمن بینایی ماشین و پردازش تصویر ایران</PublisherName>
				<JournalTitle>مجله ماشین بینایی و پردازش تصویر</JournalTitle>
				<Issn>2383-1197</Issn>
				<Volume>13</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2026</Year>
					<Month>09</Month>
					<Day>23</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Retinal Vessel Segmentation in Fundus Images under Cataract-Induced Quality Degradation Using Field-of-View-Aware Simulation and Deep Learning</ArticleTitle>
<VernacularTitle>تفکیک عروق شبکیه در تصاویر فوندوس در شرایط افت کیفیت ناشی از آب‌مروارید با بهره‌گیری از شبیه‌سازی آگاه از میدان دید و یادگیری عمیق</VernacularTitle>
			<FirstPage>1</FirstPage>
			<LastPage>18</LastPage>
			<ELocationID EIdType="pii">250550</ELocationID>
			
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>آرش</FirstName>
					<LastName>آقائی</LastName>
<Affiliation>گروه مهندسی کامپیوتر، دانشکده فنی، دانشگاه گیلان، رشت، ایران</Affiliation>
<Identifier Source="ORCID">0009-0004-5738-2166</Identifier>

</Author>
<Author>
					<FirstName>رضا</FirstName>
					<LastName>حسن زاده</LastName>
<Affiliation>گروه مهندسی برق، دانشکده فنی، دانشگاه گیلان، رشت، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-6431-758X</Identifier>

</Author>
<Author>
					<FirstName>اسدالله</FirstName>
					<LastName>شاه بهرامی</LastName>
<Affiliation>گروه مهندسی کامپیوتر، دانشکده فنی، دانشگاه گیلان، رشت، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-5195-1688</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2026</Year>
					<Month>02</Month>
					<Day>14</Day>
				</PubDate>
			</History>
		    <Abstract>Automatic retinal vessel segmentation is a fundamental component of retinal-fundus-image-based computer-aided diagnostic systems. However, the presence of cataract in a considerable portion of clinical images leads to image quality degradation and challenges the accuracy of conventional vessel segmentation methods. In this study, the main focus is on presenting a stepwise, controlled, and field-of-view-aware framework for investigating the robustness of retinal vessel segmentation algorithms under cataract-induced image quality degradation.In the first step, the physical effects of cataract, including blur, contrast attenuation, noise, and light scattering, are simulated in a controlled manner and restricted to the field-of-view region, generating image versions with different degradation severity levels. Subsequently, several representative vessel segmentation architectures are trained on the FIVES reference dataset, and the top-performing models are selected based on Dice, IoU, and Accuracy metrics. The performance of these models is then evaluated under progressively increasing cataract severity on the simulated versions of FIVES and, as a complementary analysis, on the simulated version of the classic DRIVE dataset.Due to the lack of a public standard dataset containing cataract-affected fundus images together with pixel-level vessel masks, the controlled simulation strategy enables the preservation of reference labels and provides a reproducible quantitative evaluation. Quantitative and qualitative results show that, as cataract severity increases, overlap-based metrics such as Dice and IoU gradually decrease, which reflects reduced visibility of thin vessels and lower separability between vessels and the retinal background. Nevertheless, within the defined evaluation framework, the combination of UNet with the EfficientNet-B3 encoder shows a milder performance decline than the other architectures and preserves the overall vascular structure to an acceptable extent, even at higher degradation levels.</Abstract>
			<OtherAbstract Language="FA">تفکیک خودکار عروق شبکیه یکی از مؤلفه‌های اساسی در سامانه‌های کمک‌تشخیصی مبتنی بر تصاویر فوندوس شبکیه به‌شمار می‌رود. با این حال، وجود آب‌مروارید در بخش قابل توجهی از تصاویر بالینی موجب افت کیفیت تصویر شده و دقت روش‌های متداول تفکیک عروق را با چالش مواجه می‌سازد. در این پژوهش، تمرکز اصلی بر ارائه یک چارچوب مرحله‌ای، کنترل‌شده و آگاه از میدان دید برای بررسی پایداری الگوریتم‌های تفکیک عروق شبکیه در حضور افت کیفیت ناشی از آب‌مروارید است. در گام نخست، اثرات فیزیکی آب‌مروارید شامل تاری، تضعیف تمایز، نویز و پراکندگی نور به‌صورت کنترل‌شده و محدود به ناحیهٔ میدان دید شبیه‌سازی شده و نسخه‌هایی از تصاویر با سطوح مختلف شدت تخریب تولید می‌گردند. سپس، چند معماری شاخص تفکیک عروق بر روی پایگاه‌داده مرجع FIVES آموزش داده شده و مدل‌های برتر بر اساس معیار‌های Dice،IoU و Accuracy انتخاب می‌شوند. در ادامه، عملکرد این مدل‌ها در مواجهه با افزایش تدریجی شدت آب‌مروارید بر روی نسخه‌های شبیه‌سازی‌شدهٔ FIVES و همچنین به‌صورت مکمل بر روی نسخه‌های شبیه‌سازی شده پایگاه‌دادهٔ کلاسیک DRIVE ارزیابی می‌گردد. نتایج کمّی و کیفی نشان می‌دهند که با افزایش شدت آب‌مروارید، معیارهای هم‌پوشانی نظیر Dice و IoU به‌صورت تدریجی کاهش می‌یابند؛ امری که موجب تضعیف رؤیت‌پذیری عروق باریک و کاهش تفکیک‌پذیری عروق از بافت زمینه شبکیه می‌گردد. با این حال، در چارچوب ارزیابی تعریف شده، ترکیب UNet با رمزگذار EfficientNet-B3 شیب افت عملکرد ملایم‌تری نسبت به سایر معماری‌ها نشان می‌دهد و در سطوح بالاتر تخریب نیز حفظ ساختار کلی شبکهٔ عروقی را تا حد قابل قبولی ممکن می‌سازد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">تفکیک عروق شبکیه</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تصاویر شبکیه (RF)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">آب‌مروارید (CA)</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">یادگیری عمیق</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Unet</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">شبیه‌سازی افت کیفیت تصویر</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jmvip.ir/article_250550_31eabad1b735c9b94eb6afb7d831b867.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
